Model: E15
Orginal: Jiangsu, China
Instrument classification:Class II
Warranty: 2years
Cetification: CE, ISO13485, FSC,ISO9001
E Series achieve long time monitoring, inside board also can change to separtate board : ECG Board ,Spo2 board,NIBP Board to achieve high accuracy
Low power consumption & fanless desig n can achieve high requirements of dust-off & without noise& pollution-free in clinical departments.
Optimized circuit design, reduce energy consumption, Battery run time increase 25%
WIFI with smart IT solutions
Wireless integration with Central Monitoring Station Dynamic trends provide up to 240 hours of useful information for review
8 traces per monitor and 16 monitors on one screen
View up to 32 maximum bed on one platform in real-time Review and manage patient data anytime and anywhere in and pre-hospita
Sidestream/Microstream/Mainstream e Etco2 is optional. Various option can suitable for intubated patient, cVP ventilation relied patient, non-intubated patient
2-IBP measurement with waveform, E Systoic, Diastolic, Mean Pressureon ART ICP, PA, LAP etc to fulfill differend positions invasive blood pressure measurin demands
Enables hemodynamic monitoring using thermo dilution method. be notvides an important measuremente g of the blood flow and oxygen delivery to the tissues.
|
1 x device |
|
1 x Li-Battery |
|
1 x Power line |
|
1 x Earth wire |
|
1 x User’s Manual |
|
1 x Blood oxygen probe (for SpO2, PR) |
|
1 x Blood pressure cuff (for NIBP) 1 x ECG cable (for ECG, RESP) |
|
1 x Temperature probe (for Temperature) |
|
ECG |
|
|
Input |
3/5 wire ECG cable |
|
Lead section |
I II III aVR, aVL, aVF, V |
|
Gain selection |
*0.25, *0.5, *1, *2, Auto |
|
Sweep speed |
6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
|
Heart rate range |
15-30bpm |
|
Calibration |
±1mv |
|
Accuracy |
±1bpm or ±1% (select the bigger data) |
|
NIBP |
|
|
Test method |
Oscillometer |
|
Philosophy |
Adult, Pediatric and Neonate |
|
Measurement type |
Systolic Diastolic Mean |
|
Measurement parameter |
Automatic, Continuous measurement |
|
Measurement method Manual |
mmHg or ±2% |
|
SPO2 |
|
|
Display Type |
Waveform, Data |
|
Measurement range |
0-100% |
|
Accuracy |
±2% (between 70%-100%) |
|
Pulse rate range |
20-300bpm |
|
Accuracy |
±1bpm or ±2% (select the bigger data) |
|
Resolution |
1bpm |
|
2-Temperature (Rectal & Surface) |
|
|
Number of channels |
2 channels |
|
Measurement range |
0-50℃ |
|
Accuracy |
±0.1℃ |
|
Display |
T1, T2, TD |
|
Unit |
ºC/ºF selection |
|
Refresh cycle |
1s-2s |
|
Respiration (Impedance & Nasal Tube) |
|
|
Measurement type |
0-150rpm |
|
Accuracy |
±1bm or ±5%, select the bigger data |
|
Resolution |
1rpm |
| Power requirements | |
| AC: 100 ~ 240V, 50Hz/60Hz | |
| DC: Built-in rechargeable battery | 11.1V 24wh Li-ion battery |
| Packing Information | |
| Packing size | 420mm*380mm*300mm |
| N.W. | 6kg |
| G.W. | 7.3kg |